Product data sheet
Valve
A3523-0804-R322-TH-B0,
April 4, 2025
Seat Valve electrically force-controlled
Series 35-08-TH
Valve A3523/0804/.322-TH-B0 AC, DC
The solenoid valve Type 35-TH is used for high temperatures of up to + 180 °C. It can be supplied either in brass or stainless steel and is suitable for hot water and steam applications in the plant and mechanical engineering field. The standard valve is non energized closed - NC. A non energized open -NO design can also be supplied. Temperatureresisting limit switches for both positions, i.e. OPEN and CLOSED can be added on request.
For more information follow this link:
Valve A3523/0804/.322-TH-B0 AC, DC
Datasheet explicit
Instructions
Instructions Solenoid valves, forced-operated
Stroke setting G2/DN50 Type 35/37-272/278
Solenoid coil R322
Others
separate Rectifier
Turck BIM-PST-AP6X_46240
Sensorkabel M8
Service card sensor, setting instructions
EC Declaration of Conformity
REACH Declaration
RoHS Declaration
STEP Files
035.001887_A3521-23-..04-.328-9E.stp
Videos
Version | A | |
Type of valve | 35 | Seat Valve electrically force-controlled |
Connection type, valve seat | 23 | G1/2 13mm |
Kv-value (Δp = 1 bar H₂O) | 3.8 m³/h | |
Housing | 08 | AISI 316 Ti - 1.4571(81) |
Sealing | 04 | PTFE |
Voltage type | -- | To be specified later |
Solenoid power | 32 | 21W |
Protection class | 2 | IP65 |
Valve option | TH-B0 | normally closed + Temperature design + Magnetic switch 2-fold OPEN and CLOSE inductive 3-wire N/O contact PNP |
Pressure rating | PN40 | |
System pressure | 0 - 40 bar | |
Valve type | 12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC | |
Temperature Medium | from -40 °C to 180 °C | |
Temperature Environment | from -40 °C to 40 °C | |
Mounting position | Actuator upright (preferred) or horizontal | |
Specific use case | Closed system (includes open system) | |
scope of delivery | 1 valve, 1 Connector w. rectifier & VDR EN 175301-803 A | IP65 when installed | Connectable cables Ø 4.5-11mm max.1.5mm² | 1 Solenoid Steel R322 | rotatable 360° | Valve MatchCode G0xx.xxxxxx.0xx.002.0xx | 1 connector FormA EN175301-803/A | max. current 10A | 4x90°| IP65 when installed | connectable cables Ø 5-10 mm max.1.5mm² | Valve MatchCode G0xx.xxxxxx.0xx.009.0xx | |
Valve option | TH-B0 | normally closed + Temperature design + Magnetic switch 2-fold OPEN and CLOSE inductive 3-wire N/O contact PNP |
Description | Valve opens with continuous voltage | Turck BIM-PST-AP6X_V1131_46250 | separate cable 2m with connector M8x1, 3-pin, A-coded | place of install.: top | Valve position: OPEN and CLOSE | |
Leakage rate | B - EN 12266 [Test medium air or nitrogen, 20°C room temperature] | |
REACH-RoHS conformity | REACH Yes | RoHS Yes | |
Net weight | 2.6 kg | |
Switching time (at 6 bar gas) | On: 80 ms | Off: 100 ms | |
Customs export | Customs tariff number 84818073; Country of origin Germany; ECCN (US): N; AL: N |